Home / Products / Noise Loggers & Monitoring / Gutermann ZONESCAN AMI
Gutermann ZONESCAN AMI

Gutermann ZONESCAN AMI

by Gutermann AG · 🇨🇭 Switzerland · Noise Loggers & Monitoring
Correlating Noise Logger (AMI-integrated)

Correlating acoustic loggers wire-connected into two-way fixed-network AMI systems (currently Aclara STAR and Birdz), automating daily collection and analysis of leak noise data without drive-by. Deployed on valves via magnetic base; piloted by DC Water in Washington with daily AMI data collection.

Technical specifications

Meter / product typeAMI-integrated correlating leak logger system
ApplicationPermanent fixed-network leak monitoring (AMI)
Detection methodLeak-noise correlation between neighbouring loggers (time-sync ~1 ms, ~1 m precision); spectrum analysis to reject ambient/mechanical noise
Sensor typeAcoustic noise sensor
CommunicationIntegration to AMI fixed network
Protection class (IP)IP68
Operating temperature-30 to +70°C (Aclara) / -10 to +55°C (Birdz)
Battery lifeMinimum 5 years
Outputs / softwareGutermann cloud (ZONESCAN NET)
Mounting / installationMagnetic mount on valve spindle, hydrant or fitting
Deployment typePermanent fixed network (AMI)
⚠ Specifications compiled from public manufacturer material; awaiting datasheet verification.