Home / Acoustic Leak Noise Correlators

Acoustic Leak Noise Correlators

A leak noise correlator pinpoints the position of a leak by measuring the tiny time difference between the leak sound arriving at two sensors placed on the pipe either side of it. Knowing the pipe length, material and sound velocity, the correlator computes where along the pipe the noise originates — turning 'there is a leak in this street' into 'dig here'. This page compares correlators and correlating loggers from the leading manufacturers.

31 models14 manufacturers12 source-verified

Compare 31 acoustic leak noise correlators

✓ marks models with a verified manufacturer datasheet or official source.

ProductManufacturerTypeSensorConnectivitySource
64 Seconds WaterPoint LNC264 SecondsLeak Noise Correlator—Wireless·
AQS Multi-SensorAquarius SpectrumFixed hydrophone + pressure multi-sensorHydrophone + pressure seCellular 3G/4G or CAT-M/✓
AQS-SenseAquarius SpectrumFixed acoustic correlating leak sensorAccelerometer or hydrophCellular CAT-M / NB-IoT ✓
AQS-V SensorAquarius SpectrumFixed correlating vibration (accelerometAccelerometer (vibrationCellular CAT-M / NB-IoT ✓
EchoShore-DX SystemEchologicsFixed acoustic leak-detection system (hyAcoustic sensors (hydranCellular SIM to cloud; t✓
Echologics EchoShore-DXeEchologicsFixed acoustic leak-detection node (valvExternal magnetic surfacCellular SIM to cloud; m✓
LOKAL 200 PCFASTAcoustic Correlator—Radio✓
LOKAL 400FASTAcoustic Correlator, Ground Microphone—Radio✓
FUJI DIGITAL QUATRO CORRELATOR LC-5000Fuji TecomAcoustic leak-detection device—Radio (with relay receiv·
Fuji Tecom LC-2500 CorrelatorFuji TecomLeak Noise Correlator—Radio·
DXmic ProFCSGround Microphone—Wireless, USB·
PermaNET SUFCSCorrelating Noise Logger—LTE-M / NB-IoT with 2G f✓
PermaNET TM GPSFCSHydrophone Noise Logger—Cellular, GPS-synchronis·
Tri-Corr Touch ProFCSLeak Noise Correlator—Wireless radio sensors·
AQUASCAN 760TGutermannAutomated Leak Locating Correlator with —Radio, LoRa·
AQUASCAN TM3GutermannTrunk Main & Plastic Pipe Correlator wit—Radio, LoRa·
Gutermann AQUASCAN 610GutermannLeak Noise Correlator—Wireless radio outstatio·
Gutermann HISCANGutermannHydrophone Sensor——·
MULTISCAN 2GutermannMulti-point Leak Correlator—Radio·
HEDA Leak Noise CorrelatorHEDA TechnologyLeak Noise Correlator—Radio·
PermaNet SUHWM GlobalCorrelating Noise Logger—LTE-M / NB-IoT with 2G f✓
PermaNet+HWM GlobalFixed Acoustic Leak Monitoring System—Cellular (GPRS/4G)·
SoµndSensHWM GlobalMulti-point Correlating Sensors—Bluetooth·
Touch ProHWM GlobalLeak Noise Correlator—Wireless radio outstatio·
SeCorr C 200SewerinCorrelator—wireless✓
SeCorrPhon AC 200SewerinCombination Leak Detector (Test Rod, Gro—wireless✓
Eureka5OvarroLeak Noise Correlator——✓
SebaKMT Correlux C-3SebaKMTLeak Noise Correlator—Radio·
SebaKMT Correlux P-2SebaKMTLeak Noise Correlator—Radio·
SubSurface Instruments LC-5000 QuatroSubSurface InstrumentsLeak Noise Correlator—Radio / cable·
Syrinix PIPEMINDER-TPIPEMINDERAcoustic + Pressure Monitor—Cellular·

How a leak noise correlator works

Two sensors (accelerometers or hydrophones) are coupled to the pipe at accessible points such as valves or hydrants. Leak noise travels along the pipe to both sensors; the correlator cross-correlates the two signals to find the time-of-flight difference, then combines it with the entered pipe length, diameter, material and the resulting sound-propagation velocity to calculate the leak position. Multi-point and correlating-logger systems automate this across many sensors overnight.

How to choose

Browse all acoustic leak noise correlators

Frequently asked questions

What is the difference between a noise logger and a correlator?

A noise logger listens at one point and reports whether leak noise is present in a zone. A correlator uses two sensors and the time difference between them to calculate the leak's exact position. Correlating loggers combine both: they log nightly and correlate between neighbouring units.

How accurate is leak correlation?

On metallic pipe with good sensor coupling and correct pipe data, correlators typically locate a leak to within a metre or so over moderate sensor spacings. Accuracy falls on plastic and large-diameter mains, where hydrophones and shorter spacings help.

Accelerometer or hydrophone sensors for correlation?

Accelerometers couple to the pipe wall and work well on metal and asbestos-cement pipe. Hydrophones sense the pressure wave in the water and perform better on plastic and large-diameter mains, which carry structure-borne sound poorly.

Can correlators find leaks on plastic pipe?

Yes, but it is harder because plastic transmits leak noise poorly and slowly. Hydrophone sensors, accurate sound-velocity entry, tighter sensor spacing and low-frequency filtering significantly improve results on PE/PVC mains.

Related